Back to Full-Length State Picker
FULL-LENGTH PRO EXAM

This Standard full-length exam is real pacing, real weighting, real category reports. Go Pro to unlock every Standard variant plus a personalized Study Coach.

Unlock Pro
JOURNEYMAN NEC 2023 FULL-LENGTH PRO

Journeyman Electrician Practice Test - Full-Length Test 1 (Standard 73Q/4-Hour)

A full-length, 73-question practice exam covering all 8 core NEC topic areas, weighted the same way the real exam is. A standard-length exam matching the typical multi-state PSI format. Premium — part of Full-Length Pro.

TOPICS COVERED
NEC Questions NEC Practice Tests Industrial Parallel Conductors journeyman electrician

How this test works

Read each question carefully
Look for absolute words like always / never — they often distinguish the right answer.
Manage your time
You have 240 min for 73 questions. Skip tough ones and come back.
Progress is auto-saved
Your answers are saved locally — a page refresh won't lose your work.
Review your answers
After submitting you'll see every explanation and your NEC references.

Frequently Asked Questions

Yes — completely free with no account required. All questions include detailed explanations and NEC references.

Most state Journeyman exams have 80–100 questions covering NEC code, wiring methods, branch circuits, motor controls, and load calculations.

Most states require a 70–75% passing score. This practice test uses the same 70% pass threshold so you know where you stand.

Questions are written to the 2023 NEC. Check your state licensing board to confirm which edition your state has adopted.

How to Use This Practice Test

This Journeyman Electrician Practice Test - Full-Length Test 1 (Standard 73Q/4-Hour) has 73 questions with detailed answers and NEC references. Take the full test, review every wrong answer, and look up the NEC article it references before moving on.

Tip: This is an open-book exam — tab your NEC index and Articles 210, 250, and 430 before you start.

  • Topics covered: Branch circuits, grounding, wiring methods, load calculations, and motors.
  • Passing score: 70–75% (most states). Aim for 80% on practice tests so the real exam feels easy.
  • Questions: 73 multiple-choice, one correct answer each
FULL-LENGTH PRO EXAM
73
Questions
240 min
Time
70%
Pass

Timer starts immediately. Progress is auto-saved.

About This Exam

Sized and paced to match a real state licensing exam. Finish it to get a free category-by-category score report.


Go Pro
  • Up to 15 Standard exam variants
  • Detailed topic report every time
  • Personalized study guides & Study Coach

One-time payment — $19.00, lifetime access

See Pro Plans
JOURNEYMAN · NEC 2023
Journeyman Electrician Practice Test - Full-Length Test 1 (Standard 73Q/4-Hour)
Q1 / 73
--:-- ON PACE
Auto-save 0% complete

0
Correct
0
Wrong
0s
Time

Journeyman Electrician Practice Test - Full-Length Test 1 (Standard 73Q/4-Hour) — Question List

Question 1: What is general lighting unit load per square feet for hotels and guest room?

  • 3 VA
  • 2 VA
  • 2 — VA
  • 1 VA

NEC Reference: NEC 220.12

Question 2: What is the minimum general lightening load required for 1500 square foot single family dwelling unit as permitted by NEC?

  • 4500 VA
  • 4800 VA
  • 3000 VA
  • 1500 VA

NEC Reference: NEC 220.12

Question 3: There shall be at least ............ mm airspace between wall and the door of any cabinet containing current carrying conductors whose operating voltage is less then 250 volts.

  • 6
  • 10.5
  • 14.3
  • 12.7

NEC Reference: NEC 312.11

Question 4: What must be provided for all working spaces above service equipment, switchboards and panel boards?

  • Illumination
  • Enclosures or guards
  • A protective rod
  • A water line

NEC Reference: NEC 110.26(D)

Question 5: What is the minimum tap conductor ampacity which supply 30 A industrial heating appliances?

  • 10 amperes
  • 20 amperes
  • 15 amperes
  • 18 amperes

NEC Reference: NEC 210.19(A)(4)

Question 6: Which of the following is covered by Article 670 (Industrial Machinery)?

  • A residential HVAC unit
  • A CNC machining center with multiple motors on a single frame
  • A 200A commercial panel
  • A crane in a warehouse

NEC Reference: NEC Article 670

Question 7: For equipment installed in class I location which of the following type of bonding is required?

  • A bonding jumper
  • Double ended jumper
  • hardly bonded
  • compression type bonding

NEC Reference: NEC 501.30

Question 8: At which of the following percentage the demand factor for six house hold electric cloth dryers is calculated?

  • 75 %
  • 70 %
  • 85 %
  • 80 %

NEC Reference: NEC 220.54

Question 9: When two or more conductors are installed in parallel to form a single large feeder, each individual conductor must be at least what size?

  • 4 AWG copper — any size is fine if the total is adequate
  • 2 AWG copper minimum for parallel conductors
  • 1/0 AWG copper minimum per conductor
  • 4/0 AWG copper — parallel conductors must be very large

NEC Reference: NEC 310.10(H)(1)

Question 10: Which is the minimum size copper conductor is required for the grounding electrode conductor (GEC) connected to a ground rod

  • 6 AWG
  • 8 AWG
  • 4 AWG
  • 16 AWG

NEC Reference: NEC 250.166(A)

Question 11: Which of the following type of conductor is used to supply a 40 ampere single phase motor used for continuous duty applications?

  • No 8 THW
  • No 6 THW
  • No 12 THW
  • No 14 THW

NEC Reference: NEC 310.16

Question 12: Which of the following is the minimum clear workspace that shall be provided to electrical equipment rated at 601 volts that has exposed live parts on its both sides?

  • 3 feet
  • 4 feet
  • 5 feet
  • 6 feet

NEC Reference: NEC 110.34

Question 13: what is the maximum over current device rating that is allowed to placed — to protect panel board instrumentation circuit?

  • 30 amperes
  • 15 amperes
  • 20 amperes
  • 10 amperes

NEC Reference: NEC 408.52

Question 14: A 50 HP 460 volts three phase AC motor is supplied with THWN conductors. Which is of the following is the size of the branch circuit conductors?

  • 81.25 amperes
  • 74.75 amperes
  • 70 amperes
  • 85 amperes

NEC Reference: NEC 430.250

Question 15: What are the minimum heavy duty lamp holders that are permitted on 20 ampere branch circuit operated at 120 volts?

  • 2
  • 1
  • 3
  • 4

NEC Reference: NEC 220.21(A)

Question 16: What is the maximum rating of panel boards containing 30 ampere or less snap switches?

  • 30 amperes
  • 120 amperes
  • 45 amperes
  • 200 amperes

NEC Reference: NEC 408.36(A)

Question 17: Dry type transformer rated more than ............... are permitted to install in hollow spaces of buildings.

  • 50 KVA
  • 100 KVA
  • 85 KVA
  • 75 KVA

NEC Reference: NEC 450.13(A)

Question 18: What is the the minimum size copper wire that can be used for outside overhead wiring, if the wire carries more than 600 volts?

  • No. 6 AWG
  • No. 8 AWG
  • No. 10 AWG
  • No. 12 AWG

NEC Reference: NEC 225.6(A)(2)

Question 19: A single phase 5ph , 230 volts motor has name plate full load rating of 40 amp. What is its overload protection device rating in amperes?

  • 46 amperes
  • 40 amperes
  • 50 amperes
  • 60 amperes

NEC Reference: NEC 430.32

Question 20: The diagram shows a 480–208Y/120V transformer feeding a subpanel 40 feet away. The system bonding jumper is installed at both the transformer secondary and at the subpanel neutral-ground bus. What is wrong with this installation?

  • Nothing is wrong — double bonding improves safety
  • The system bonding jumper can only be at one location, not both
  • The transformer secondary does not need a system bonding jumper
  • The subpanel is too far from the transformer for this wiring method

NEC Reference: NEC 250.30(A)(1)

Question 21: A 4 11/16–1 1/2 square box has a volume of 29.5 cu in. Maximum number of 12 AWG conductors permitted per Table 314.16(A) (no devices, clamps, or fittings counted)?

  • 9
  • 11
  • 13
  • 15

NEC Reference: NEC Table 314.16(A)

Question 22: Under certain conditions equipment grounding conductors are considered as current carrying conductors.

  • True
  • False

NEC Reference: NEC 310.15(B)(5)

Question 23: The panel diagram shows a 120/240V panel with a multiwire branch circuit. Circuit 1 is a single-pole 20A breaker with a black wire and circuit 3 is a single-pole 20A breaker with a red wire — both share a white neutral wire. Is this panel wiring correct?

  • Yes — two single-pole breakers are fine if they are on opposite legs
  • No — a handle tie or 2-pole breaker is required for multiwire branch circuits
  • Yes — as long as the neutral is the same color throughout
  • No — multiwire branch circuits are not permitted in residential panels

NEC Reference: NEC 210.4(B)

Question 24: A central A/C condensing unit nameplate shows a branch-circuit selection current of 24A. What is the maximum overcurrent device allowed on its branch circuit?

  • 30A
  • 40A
  • 45A
  • 60A

NEC Reference: NEC 440.22(A)

Question 25: What is the minimum size electrical service is required for a single family dwelling unit?

  • 100 amperes
  • 50 amperes
  • 150 amperes
  • 175 amperes

NEC Reference: NEC 230.79(C)

Question 26: When two ground rods are installed as a supplemental electrode system, what is the minimum spacing required between them?

  • 3 feet apart
  • 6 feet apart
  • 8 feet apart
  • 10 feet apart

NEC Reference: NEC 250.53(B)

Question 27: The overhead clearance diagram shows a service drop crossing over different areas. Point A is above a sidewalk at the entrance to a house. Point B is above the driveway at the same house. Point C is above an alley used by delivery trucks. Which clearance is violated?

  • Point A at 11 feet is a violation — pedestrian entrance needs 10 feet minimum (compliant, actually)
  • Point C at 16 feet is a violation — truck traffic alley needs 18 feet minimum
  • Point B at 12 feet is a violation — residential driveway needs 15 feet minimum
  • No violations — all three points meet their clearance requirements

NEC Reference: NEC 230.24(B)

Question 28: The following materials shall not be used as Grounding electrodes.

  • Copper
  • Metal
  • Aluminum

NEC Reference: NEC 250.52

Question 29: The NEC defines a continuous load as a load that is expected to continue without interruption for at least:

  • 1 hour
  • 2 hours
  • 3 hours
  • 8 hours

NEC Reference: NEC Article 100 (Definitions)

Question 30: The outline lighting system shall be at least .............. feet above the areas accessible to vehicles unless protected from physical damage.

  • 14
  • 12
  • 8
  • 15

NEC Reference: NEC 600.9

Question 31: An instantaneous-trip circuit breaker (used for motor branch circuits) has no intentional time delay. What is the main advantage of this type of breaker?

  • It provides overload protection without a relay
  • It trips quickly on fault current but does not trip on motor inrush
  • It can be used without any other motor protection
  • It is the only type allowed for residential use

NEC Reference: NEC 430.52(C)(3)

Question 32: A pull box has a 3-inch conduit and a 2-inch conduit entering the same wall and making an angle pull. What is the minimum distance from the 3-inch conduit to the opposite wall?

  • 18 inches — 6–3-inch conduit only
  • 20 inches — 6–3-inch plus the 2-inch conduit diameter
  • 24 inches — 8–3-inch conduit
  • 30 inches — 6 — (3 + 2) combined

NEC Reference: NEC 314.28(A)(2)

Question 33: What is permissible voltage drop in percentage for combination of both feeders and branch circuit conductors?

  • 2 %
  • 3 %
  • 5 %
  • 8 %

NEC Reference: NEC 215.2(A)(4)

Question 34: What size service entrance conductors are required for 250 A continuous three phase load if the terminals are at ambient temperature of 70 C?

  • 3/0 AWG
  • 250 kcmil
  • 400 kcmil
  • 2/0 AWG

NEC Reference: NEC 312.5

Question 35: Which of the following is the minimum size of copper grounding conductor that shall be used in marina?

  • No 12 AWG
  • No 8 AWG
  • No 10 AWG
  • No 6 AWG

NEC Reference: NEC 550.15

Question 36: What is the minimum volt ampere rating of a 110,000 square foot school?

  • 330 KVA
  • 220 KVA
  • 165 KVA
  • 440 KVA

NEC Reference: NEC 220.12

Question 37: What is the maximum ampere rating of a power supply feeder of mobile homes?

  • 25 amperes
  • 50 amperes
  • 75 amperes
  • 45 amperes

NEC Reference: NEC 550.10

Question 38: What is the maximum voltage applied to — branch circuits that are connected to luminaries in dwelling unit?

  • 120 volts
  • 240 volts
  • 150 volts
  • 480 volts

NEC Reference: NEC 210.6

Question 39: Which of the following is the size of single supply-side bonding jumper is required for three metal raceways, each containing 300 kcmil service conductors?

  • 2 AWG
  • 3 AWG
  • 1/0 AWG
  • 1 AWG

NEC Reference: NEC 250.102(C)(1)

Question 40: Over current protection is not required at the point where the wire size is not over 25 — feet.

  • True
  • False

NEC Reference: NEC 240.21

Question 41: A lighting unit is connected on a 20 ampere branch circuit on which a fastened-in place appliance is located. What is the maximum percentage branch circuit rating is permitted on the appliance?

  • 80 %
  • 70 %
  • 50 %
  • 60 %

NEC Reference: NEC 210.23(A)(2)

Question 42: What is the minimum size electrical service required for a single family dwelling unit?

  • 100 amperes
  • 150 amperes
  • 200 amperes
  • 50 amperes

NEC Reference: NEC 230.79(C)

Question 43: Eight 10 AWG THWN conductors (35A ampacity each) are all installed in the same conduit, and all eight are current-carrying. What is the adjusted ampacity for each conductor?

  • 24.5A — 35A × 0.70 (7–9 conductor factor)
  • 28A — 35A × 0.80 (4–6 conductor factor)
  • 31.5A — 35A × 0.90
  • 35A — no derating needed for 10 AWG

NEC Reference: NEC Table 310.15(C)(1)

Question 44: How many 20 Amp circuits are required for a 2500 sq.ft dwelling unit?

  • 3
  • 4
  • 5
  • 2

NEC Reference: NEC 220.12

Question 45: The pool diagram shows a wet-niche luminaire installed in the pool wall 18 inches below the waterline. What is the maximum voltage allowed between conductors for a wet-niche pool luminaire?

  • 120V
  • 150V
  • 240V
  • No limit — the fixture listing determines the voltage

NEC Reference: NEC 680.23(B)(1)

Question 46: Per NEC 300.4(D), where cables or raceways are installed parallel to framing members, the nearest outside surface of the cable or raceway shall not be less than _____ inches from the nearest edge of the framing member, or shall be protected from screws and nails by a steel plate.

  • 1 inch
  • 1 — inches
  • 1 — inches
  • 2 inches

NEC Reference: NEC 300.4(D)

Question 47: The lamp holder connected to a 30 amp branch circuit must be of heavy-duty type.

  • True
  • False

NEC Reference: NEC 210.21(A)

Question 48: For stationary small motors rated less than .................., the branch circuit over current device — may serve as a controller.

  • 1/2 horsepower
  • 1/ 8 horse power
  • 1 horsepower
  • 5 horse power

NEC Reference: NEC 430.81

Question 49: A feeder serves a heating load of 30 kW and a cooling load of 22 kW, both not in use at the same time. For service-load calculations, the value used is:

  • Sum of both = 52 kW
  • Average = 26 kW
  • Larger only = 30 kW
  • 125% of larger = 37.5 kW

NEC Reference: NEC 220.60

Question 50: What is the maximum branch circuit load for a 10 kW single electric range in a dwelling unit?

  • 8 kW
  • 10 KW
  • 7 KW
  • 6 KW

NEC Reference: NEC 220.555

Question 51: What is the minimum feeder or service load for cloth dryers in a dwelling unit?

  • 5000 watts
  • 2500 watts
  • 4000 watts
  • 6500 watts

NEC Reference: NEC 220.54

Question 52: The equipotential bonding grid for a permanently installed swimming pool must use a solid copper conductor no smaller than:

  • 12 AWG stranded copper
  • 10 AWG solid copper
  • 8 AWG solid copper
  • 6 AWG stranded aluminum

NEC Reference: NEC 680.26(B)(2)

Question 53: What is the minimum free space required for No 12 AWG conductor with in the metal box?

  • 2.25
  • 2.5
  • 2
  • 1.75

NEC Reference: NEC 314.16(B)

Question 54: What is the maximum instantaneous voltage that a low voltage lighting system cannot exceed under any load conditions?

  • 34 volts
  • 30 volts
  • 38.2 volts
  • 42.4 volts

NEC Reference: NEC 411.2

Question 55: An orange receptacle in a hospital patient care area is called an isolated-ground receptacle. What is it used for?

  • To provide GFCI protection for medical equipment
  • To reduce electrical noise on the ground path for sensitive medical equipment
  • To mark 20A circuits so staff know they are on the critical branch
  • To allow the use of 240V equipment at a standard 120V outlet

NEC Reference: NEC 517.16

Question 56: If 30 ampere or less snap switches are equipped in panelboards, they must be protected not in excess of:

  • 30 amperes
  • 150 amperes
  • 200 amperes
  • 225 amperes

NEC Reference: NEC 408.36(A)

Question 57: In which of the following devices the delta breakers cannot be installed?

  • Panel boards
  • Conduit boxes
  • metal boxes
  • Enclosures

NEC Reference: NEC 408.36

Question 58: The grounding electrode conductor (GEC) connecting to a ground rod does not need to be larger than what size copper conductor?

  • 4 AWG copper
  • 6 AWG copper
  • 8 AWG copper
  • 10 AWG copper

NEC Reference: NEC 250.66(A)

Question 59: When the motor nameplate is not available, which NEC table gives the full-load current for 3-phase AC induction motors?

  • Table 310.16
  • Table 430.248
  • Table 430.250
  • Table 430.52

NEC Reference: NEC Table 430.250

Question 60: What is the minimum ampere rating of short circuit ground fault protective device that can be used for individual motor-compressor?

  • 12 amperes
  • 15 amperes
  • 20 amperes
  • 18 amperes

NEC Reference: NEC 440.22(A)

Question 61: Per 690.12, rapid shutdown of a roof-mounted PV array on a one-family dwelling must reduce voltages outside the array boundary to:

  • 30V or less within 30 seconds
  • 50V or less within 60 seconds
  • 0V immediately
  • 120V or less within 5 seconds

NEC Reference: NEC 690.12

Question 62: A cord and plug device used as disconnecting means for a motor must be rated for ..................

  • Horsepower
  • voltage
  • Resistance
  • Current

NEC Reference: NEC 430.109(F)

Question 63: The general lighting load in Volt-ampere/Sq.Foot that a church building requires is ..............

  • 1 Volt-Ampere/ Sq.Foot
  • 2 Volt-Ampere/ Sq.Foot
  • 3 Volt-Ampere/ Sq.Foot
  • 4 Volt-Ampere/ Sq.Foot

NEC Reference: NEC 220.12

Question 64: The ungrounded ducts or conduits should be sealed before entering buildings.

  • True
  • False

NEC Reference: NEC 230.8

Question 65: What is the adjustment ampacity of a 3/0 THWN conductors in a wet location, if the raceway contains seven conductors in it?

  • 122.5 amperes
  • 125.5 amperes
  • 140 amperes
  • 133 amperes

NEC Reference: NEC 310.15(B)(16)

Question 66: The 10-foot feeder tap rule (240.21(B)(1)) allows a smaller conductor to be tapped from a feeder without an OCPD at the tap point. What is a key condition that must be met?

  • Tap conductors must be in free air only, not in conduit
  • Tap conductors must be at least 1/10 the rating of the feeder OCPD and enclosed in a raceway
  • Tap conductors must match the ampacity of the full feeder
  • Tap conductors longer than 10 feet are acceptable if in conduit

NEC Reference: NEC 240.21(B)(1)

Question 67: A 480V service has 25,000A available SCC. The minimum AIC rating of OCPDs at the service must be:

  • 10,000A AIC
  • 14,000A AIC
  • 25,000A AIC or higher
  • No AIC rating required for service equipment

NEC Reference: NEC 110.9

Question 68: Per 445.13, the conductors running from a generator output terminals to the first overcurrent device must be sized at what percentage of the generator nameplate current rating?

  • 100%
  • 115%
  • 125%
  • 150%

NEC Reference: NEC 445.13

Question 69: Mutli-wire branch circuits shall be permitted in class I division I locations.

  • True
  • False

NEC Reference: NEC 501.40

Question 70: What is the maximum support interval for a 2-inch rigid metal conduit (RMC) run?

  • 10 feet
  • 12 feet
  • 16 feet
  • 20 feet

NEC Reference: NEC Table 344.30(B)(2)

Question 71: What is the primary protection required for a 2 wire 480V to 120 V Transformer rated at 900 VA?

  • 5 A
  • 6 A
  • 4 A
  • 3 A

NEC Reference: NEC 450.3

Question 72: The maximum overcurrent device size for a 10 AWG copper conductor used in a branch circuit is:

  • 20A
  • 25A
  • 30A
  • 40A

NEC Reference: NEC 240.4(D)(1)

Question 73: What is the general lighting unit load for a 6000 square foot hospital?

  • 12000 Volt-Ampere
  • 6000 Volt-Ampere
  • 18000 Volt-Ampere
  • 3000 Volt-Ampere

NEC Reference: NEC 220.12

Key NEC References for This Test

ArticleWhat It Covers
Art. 100Definitions — know: feeder, branch circuit, OCPD, dwelling unit
Art. 210Branch Circuits — GFCI/AFCI locations, circuit ratings, outlet spacing (most tested)
Art. 220Load Calculations — dwelling unit standard method
Art. 250Grounding & Bonding — GEC sizing, electrode system, EGC
Art. 310Conductors — ampacity (Table 310.12), insulation, derate rules
Art. 430Motors — conductor 125% FLA, OCPD 250% FLA, overloads, disconnects
Study Tip: Tab Articles 210, 250, and 430 in your NEC before the exam. Know the Table 310.12 ampacity values for 14, 12, 10, 8, 6, and 4 AWG copper.
WHY GO PRO

Every Standard Variant. One Real Result.

You just practiced on one full-length, Standard-style exam built to mirror the real licensing test — timing, weighting, and difficulty included.

Up to 15 Standard ExamsEvery test variant, one purchase
Detailed ReportsEvery attempt, topic-by-topic
Study CoachA personalized plan that adapts to you

One-time payment — $19.00, lifetime access to Standard

Unlock Pro
EXAM CARD JOURNEYMAN FULL-LENGTH PRO
Questions73
Time limit240 min
Pass score70%
Code editionNEC 2023
DifficultyIntermediate
Last reviewedJun 2026

Timer starts immediately. Progress is auto-saved.

Source: NEC 2026 (NFPA 70)
About This Exam

Sized and paced to match a real state licensing exam. Finish it to get a free category-by-category score report.


Go Pro
  • Up to 15 Standard exam variants
  • Detailed topic report every time
  • Personalized study guides & Study Coach

One-time payment — $19.00, lifetime access